Weighing Controller Force Measuring

Weighing Controller Force Measuring
Product Detailed
1. For:Peak Hold Value / Valley Hold Value / Force Value AO or Digit Output; 2. Good quality an good price;

²  Application I: Used for the Force Measuring System with Peak&Valley Hold Value detection, display, print and AO output.

²  Application II: Used as a high-speed data collector with max. Sampling Frequency 800Hz, for outputting Instantaneous Force Value or Instantaneous AD value to the Force Value analysis computer by the digit communication port with max. boud rate 115.2kbps.

²  The force measuring process can be controlled by DI input switch, keypad and Command from communication port.

²  EMC design with high anti-jamming capability, suitable for industrial environment.

²  16-bit green VFD digit display screen with English character display.

²  Menu&Shortcut mode operation with key tone.

²  24-bit High-precision and high-speed A/D conversion module with 60,000 internal code [AD value] used and Max.800Hz sampling frequency.

²  Max. Connection Quantity: 8 Loadcells (350Ω).

²  Data Calibration and Load Calibration available.

²  Auto-locking, Key-locking, Key-unlocking, Digital Setting&Calibration and I/O Testing functions available.

²  1 Optional and definable analog signal output [AO: 4~20mA].

²  3 Normally open switch inputs [DI] and 5 normally open relay switch outputs [DO].

²  2 Optional communication ports for linking to IPC/PLC, remote display&operation terminal, serial printer and wireless module.

²  Support industry configuration software, e.g. iFix.

²  The Force Record can be printed automatically and manually.

²  With the multitasking mode, the measuring&control process will not be interrupted by parameter setting and the other operations.

²  Once the internal temperature exceeds 45°C, the cooling fan will work automatically for avoiding overheating under the high temperature environment.



Copyright Notice @ 2008-2022 ECOL Limited and/or its subsidiaries and licensors. All rights reserved.